Technical Specifcations
CLASSIFICATION | PERFORMANCE/PARAMETER | |
Pipe | Materials | Steel, Stainless Steel, Cast Iron. Plastics, Concrete, etc. |
Inner Diameter | 0.5 to 236 in. (15 ~ 6000mm) | |
Straight Pipe Section Requirement |
10D upstream, 5D downstream (required length may be longer depending on site conditions) |
|
Fluid | Types | Clean, sonically conductive |
Turbidity | Smaller than 10,000ppm (mg/l) with a low level of air bubble content |
|
Temperature | -4° F to 140° F (-20° C to 60° C) | |
Flow Velocity | -53 to +53 ft/s (-16 to +16 m/s) | |
Transducer | Pipe Size Range | S: 0.5 to 4 in. (15 ~100mm) |
M: 2 to 40 in. (50 ~ 1000mm) | ||
L: 12 to 236 in. (300 ~ 6000mm) | ||
Mounting Method |
‘V’ method: Suitable for pipe sizes 16 in. (400mm) or smaller | |
‘Z’ method: Suitable for pipe size 10 in. (250mm) or larger | ||
Cable Length | 16 ft (5m) Std. ( longer lengths available) | |
Flow Computer | Display | Alphanumeric |
Keyboard | 4×4 keypad | |
Mounting | Wall Mount or optional Panel Mount | |
Output | 4-20mA or 0-20mA analog output, frequency output (12- 9999Hz), relay, serial output |
|
Power | Wall Mount: 120VAC or24VAC | |
Dimension | Wall Mount: 9.9 x 3.6 x 3.2 in. (251 x 92 x 80mm) | |
Weight | 7 lbs. (3kg) Wall Mount | |
Operating Condition | Temperature | Flow Computer: -4 to158°F (-20 to 70°C) Transducers: -4 to 140°F (-20 to 60°C) |
Humidity | Flow Computer: 85% RH at 104°F (40°C) Transducers: 98% RH at 104°F(40°C) (water submersible up to 3 m) |
|
Performance | Accuracy | ±1.0% of reading above ±1 ft/s |
Repeatability | ±0.2% at 1 to 53 ft/s (0.3 ~16m/s) | |
Linearity | 0.5% |